PRESS MATCHER 4.4 - Hotfixes ____________________________ [Microsoft Edge Download Warning] When downloading a hotfix from the CGS ORIS website, Microsoft Edge may display the following warning: " isn't commonly downloaded. Make sure you trust before you open it." This warning is generated by Microsoft Defender SmartScreen and is based on the file's current reputation. It does not indicate that the file contains malware. The warning commonly appears for newly released, recently updated, or not yet widely distributed files. To allow the download and confirm the file as safe, follow these steps: 1. Move the cursor over the download warning in Edge. 2. Click the "..." (More actions) button. 3. Select "Report this file as safe". 4. Choose "I think this is a safe website". 5. Complete the CAPTCHA verification. 6. Click "Submit" to send feedback to Microsoft. 7. Click the Downloads icon in Edge. 8. Move the cursor over the download warning again. 9. Click "..." again and select "Keep". 10. In the confirmation dialog, select "Keep anyway" from the menu of the "Delete" button. 11. If a Windows installation warning appears, click "More information" and then select "Run anyway". [Installation] Certain programs may block the installation process. The process pauses after extracting the installation files. In this case proceed as follows: 1. Exit antivirus program. 2. If the current version of Adobe Creative Cloud is installed, exit the Adobe Creative Cloud desktop app. Do this by selecting 'File -> Exit Creative Cloud', then click 'Quit' to stop all background processes. 3. Start Windows Task Manager and click the 'Details' tab. Right-click 'Setup.exe' and select 'Analyze wait chain'. The process listed under 'Setup.exe' is blocking the installation. Select and end it. Version 4.4.0.7 #PM-3 - PDF output: Fixed a rendering issue in PDF output files that caused visual artifacts and gaps in fonts. #PM-5 - PDF output: Resolved a rendering issue where certain font characters were displayed incorrectly on iPhones and other Apple devices. #PM-16 - TIFF output: Added an 'Embed profile' option for ORIS_DAT-based color corrections, allowing users to embed the target ICC profile of the ORIS_DAT color table into the TIFF output file. This feature is only supported for ORIS_DAT files created with a target ICC profile, e.g. via the 'ICC Color Transformation' tool, and is not compatible with ORIS_DAT files resulting from iterative color matching processes. Version 4.4.0.6 #PM-7 - PDF output: Fixed a rendering issue in PDF Color Correction queues that caused visual artifacts and gaps in fonts. #PM-24 - PDF output: Fixed an issue where some font characters were missing when processed via PDF Color Correction queues. #PM-34 - PDF output: Fixed several font rendering and handling issues that occurred when processing multi-page PDF files. Version 4.4.0.5 #68541 - PDF output: Omitting grayscale images works as expected now. #68732 - Spot colors with Lab equivalents are now output correctly when the target color space is CMYK+. Version 4.4.0.4 #68579 - PDF output: PRESS MATCHER no longer produces unintended black areas for certain PDF/X-4 files created with InDesign. Version 4.4.0.3 #68319 - The 'New' button in the 'Additional Options' dialog (accessed via the 'Set' button on the 'Color Correction' tab) now correctly opens the 'Spot Color Correction' dialog. #68312 - X GAMUT only: When you modify the 'SCTV gamma factor' under 'File > Preferences > Multi-channel linearization', it no longer resets to '1' after restarting X GAMUT. #68389 - Online help is also available in German now. Version 4.4.0.2 Additions available for X GAMUT only: #66911 - Multi-channel linearization: It is now possible to select a gamma factor for SCTV under 'File > Preferences > Multi-channel linearization'. #68274 - ICC Device Link profiles: You can now specify the number of CLUT nodes when creating a device link profile using the 'Utilities' menu. Version 4.4.0.1 #68198 - PDF output: Layers were missing under certain conditions. #68203 - i1iO Pro 3: When you press the 'Stop' button, the arm that holds the i1 moves back to the calibration tile as expected. #68212 - New multi-channel ICC profile for FOGRA55: Ref-ECG-CMYKOGV_FOGRA55_TAC300.icc This profile is available in the installation directory …\CGS\Common Files\ICC\.